ICU Setup At Home in Agra

Product related to ICU Setup At Home

Portable Ventilator in Agra

Brand Philips
Model Trilogy 100
Environmental Temperature - 5 Degree Celsius - 40 Degree Celsius
Relative Humidity - 15% - 95%
Atmospheric Pressure - 110kPa - 60kPa
Physical Weight - 11 Lbs, 5 Kg
Size - 4.5 x 6.88 x 9.5 in
16.69 x 38.45 x 22.52 cm
Controls Circuit Types - Active With PAP, Passive
Ventilation Types - Volume Controls, Pressure Control, Bilevel
Volume Modes - AC, SIMV (w/PS), CV
Pressure Modes - CPAP, S, S/T, T, PC-SIMV (w/PS)
IPAP - 4-50 cm H2O
EPAP - 0-25 cm H2O For Active Circuits, 4-25 cm H2O For Passive Circuits
CPAP - 4-20 cm H2O For Passive Circuits
PEEP - 0-25 cm H2O For Active Circuits, 4-25 cm H2O For Passive Circuits
Pressure Support Differential - 0-30 cm H2O
Tidal Volume - 50-2000 ml
Breath Rate - 0-60 For AC Mode, 1-60 For All Other Modes
Inspiratory Time - 0.3-0.5 Secs
Rise Time - 1-6
Ramp Start Pressure - 0-25 cm H2O For Active Circuits, 4-25 cm H2O For Passive Circuits, 4-19 cm H2O In CPAP Mode
Ramp Length - Off, 5-45 Minutes
Flex - Off, 1-3
Flow Trigger Sensitivity - 1-9 L/Min
Flow Cycle - 10% - 40%
Apnea Rate - 4-60 BPM
Measured Patient Parameters Tidal Volume - 0-2000 ml
Minute Ventilation - 0-99 L/Min
Leak Rate - 0-200 L/Min
Respiratory Rate - 0-80 L/Min
Peak Inspiratory Flow - 0-200 L/Min
Peak Inspiratory Pressure - 0-99 cm H2O
Mean Airway Pressure - 0-99 cm H2O
% Patient Triggered Breaths - 0-100 %
I:E Ratio - 9.9:1 to 1:9.9
Alarms Circuit Disconnect - Off, 10-60 Secs
Apnea - Off, 10-60 Secs
High Tidal Volume - Off, 50-2000 ml
Low Tidal Volume - Off, 50-2000 ml
High Minute Ventilation - Off, 1-99 L/Min
Low Min Ventilation - Off, 1-99 L/Min
High Respiratory Rate - Off, 4-80 BPM
Low Respiratory Rate - Off, 4-80 BPM
Available Rental & Sale
Get Best Quote Request A Callback

Ventilator in Agra

Brand Resmed
Model Astral 150
Indications For Use Life Support For Patients Over 5Kg
CIRCUIT Single Circuit With Leak
Single Circuit With Valve
Double Circuit
THERAPY Valve Circuit Therapy - CPAP, ACV, PACV, P-SIMV, V-SIMV, PS
Leak Circuit Therapy - CPAP, ST, PAC
Manual Breath
Sigh Breath (Recruitment)
Apnoea Ventilation - Volume And Pressure
Preset Programs - 4
PRESSURE RANGE AND SETTINGS Delivered Pressure (cm H2O) - 2-50 (Leak Circuit), 0-50 (Valve Circuit)
Delivered Tidal Volume (cm H2O) - Adult 100 to 2500 ml, Paediatric 50 to 300 ml
Respiratory Rate - Adult Off 2 to 50 bpm, Paediatric Off 5 to 80 bpm
DATA SpO2 Monitoring - Optional
FiO2 Monitoring
7 Days Of High-Resolution Data With 25 Hz Pressure Flow - On Screen And Download
365 Days Of Summary Data - On Screen And Download
ALARMS A Wide Range Of Settable Alarms Are Available Including FiO2 And SpO2 When Connected
DIMENSIONS Weight - 3.2 Kg
Dimensions (L x W x H) - 285mm x 215mm x 93mm
Internal Battery - Lithium-Ion Battery, 14.4V, 6.6 Ah, 95 Wh. 8 Hrs. Backup Power
Sound Power Level - 43 +/- 3 dBA*
Sound Pressure Level - 35 +/- 3 dBA*
IEC 60601-1 CLASSIFICATION Medical Electrical Equipment - General Requirements For Basic Safety And Essential Performance -
Class II (Double Insulation) Type BF Continuous Operation Suitable For Use With Oxygen
Available Rental & Sale